ORIGINAL ARTICLE
-
J Korean Dent Assoc. 2020;58(12):726-736. Published online November 30, 2020.
DOI: https://doi.org/10.22974/jkda.2020.58.12.001
- Primer가 이중중합 레진시멘트의 중합에 미치는 영향
-
이은혜
, Enkhbileg Nyamsuren
, 김진우
, 조경모
, 박세희
-
강릉원주대학교 치과대학 치과보존학교실
-
- Effect of primer on the polymerization of dual cure resin cements
-
Eun-Hye Lee
, Nyamsuren Enkhbileg
, Jin-Woo Kim
, Kyung-Mo Cho
, Se-Hee Park
-
Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University
-
- Corresponding author: Se-Hee Park Tel: +82-33-640-2760, Fax: +82-33-640-3103, Email: drendo@gwnu.ac.kr
- Received: June 1, 2020; Revised: July 24, 2020 Accepted: August 14, 2020.
- Abstract
- Objectives
The primer (G-Cem One Adhesive Enhancing Primer), which promote self-polymerization more in the absence of polymerization light is developed. To date, many studies on the mechanical properties and prognosis of various self-adhesive resin cements have been published. Since there is almost no comparison of the degree of polymerization depending on the application of primers, this study was attempted.
Materials and Methods
A total of three types of dual cure self-adhesive resin cements (G-Cem One, G-Cem LinkAce, Rely-X U200) and one type of dual cure resin cement (Rely-X Ultimate) were evaluated. G-Cem One Primer was used as a primer enhancing of auto-polymerization. A mold 5 mm in diameter and 2 mm thick was made from aluminum, primers were applied on a glass slit, and each material was filled in the mold, and self-polymerization was induced. The microhardness was measured with a Vickers microhardness machine after 10 minutes, 1 hour,3 hours,6 hours and 24 hours. All dates were statistically analyzed.
Results
G-Cem One, G-Cem LinkAce and Rely-X U200 showed high microhardness values when primers were applied at the beginning of cement mixing. Primer application did not show significantly different in Rely-X Ultimate.
Conclusion
The application of a new primer has a dual cure self-adhesive resin cement which promotes the polymerization at the beginning of the mixing.
Keywords :dual cure resin cement; hardness test; polymerization; primer; self-cure